Repository navigation
docs: fix relay polarity (active-low) and remove non-existent relay-invert setting - #238
Conversation
…nvert setting The firmware drives standard external relay modules active-low (PoolController.cpp) and has no runtime relay-invert option. The hardware guide, quick start guides, build-from-zero, troubleshooting and the production checklist said the opposite (must be active-high / relay-invert). Also label the hardware guide cost total correctly (it includes the optional parts). Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG
Codex Review SummaryThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
✅MegaLinter analysis: Success
Notices
See detailed reports in MegaLinter artifacts Your project could benefit from a custom flavor, which would allow you to run only the linters you need, and thus improve runtime performances. (Skip this info by defining
|
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG
docs/quick-start.md, docs/quickstart.md (German) and docs/faq.md duplicated the maintained pages on smart-swimmingpool.com and had drifted (relay polarity, cost). README, CONTRIBUTING and the docs index now link to the website. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG

Requested by Stephan · project thread
Summary
Found while consolidating the website docs (website#73): the docs in this repo contradict each other and the firmware on relay polarity.
src/PoolController.cpp). Only the NORVI AE01-R and Olimex builds use active-high relays. There is no runtime relay-invert option.hardware-guide,quick-startandquickstartsaid the module must be active-high.build-from-zero,troubleshootingandproduction-checklistreferred to a non-existentrelay-invertsetting. All now say: active-low module (or HIGH/LOW jumper on LOW), no runtime inversion. EN and DE.Duplicate pages removed
docs/quick-start.md,docs/quickstart.md(German) anddocs/faq.mdduplicated the maintained pages on smart-swimmingpool.com and had drifted. They are deleted; README, CONTRIBUTING(.de) anddocs/_index.mdnow link to the website pages. The website import (website#73) no longer rewrites quickstart links into the pool-controller section.Lint
Pre-existing markdownlint errors in touched/neighbouring files are fixed; MegaLinter is green.
Please verify
Confirm on a real build that a standard HW-279-style module is driven LOW = ON. The firmware source says so; hardware was not tested.
🤖 Generated with Claude Code
https://claude.ai/code/session_018328o8Q4ZG13zRaqWob4aG