4 changes: 1 addition & 3 deletions .codespellrc
Original file line number Diff line number Diff line change
@@ -1,5 +1,3 @@
[codespell]
ignore-words-list = ot
skip = **/sunspec/models/smdx/smdx_*.xml,
**/sunspec/models/smdx/CHANGELOG,
**/templates/mydesigner/**
skip = **/templates/mydesigner/**
4 changes: 2 additions & 2 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -22,14 +22,14 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
- **SCEPTRE App**: Type annotations on every app function, `Final` on module constants.
- **SCEPTRE App**: Validation failures raise `error.AppError` instead of calling `sys.exit(1)`, matching the app contract.
- **SCEPTRE App**: `metadata.simulator` matches case-insensitively in both stages, as validation already did; a miscased name used to silently get the default config.
- **Build System**: `package-data` now ships the SunSpec models, the `mydesigner` SCADA tree and the infrastructure table; an installed wheel was missing all three.
- **Build System**: `package-data` ships the `mydesigner` SCADA tree and infrastructure table.

### Removed
- **SCEPTRE App**: The `reg_config` manual register-map path. It was dead code: the app never populated it, so every device always took the automatic numbering branch. Output is unchanged.
- **SCEPTRE App**: SunSpec has been burned away by the SCORCHing heat of 3000 Suns and thus no longer exists in this repo.

### Fixed
- **SCEPTRE App**: With more than one PowerWorld provider, only the last one's `hil_tags` reached the object list, and only the last one's `objects.txt` was written. Tags now aggregate across providers and every PowerWorld provider gets the combined `objects.txt`.
- **SCEPTRE App**: Every `sunspec` inverter raised `KeyError`: the SunSpec register mappings are keyed `PowerDistribution` but received `power-distribution`. The whole protocol was unusable.

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LOL

- **SCEPTRE App**: `fep` hosts raised `TypeError`, built without the required `device_subtype`.
- **SCEPTRE App**: Per-device register overrides raised `RuntimeError` in `SceptreMetadataParser`, which popped keys while iterating a live dict view.
- **SCEPTRE App**: A `power-transmission` inverter raised `TypeError`, passing `infrastructure` twice into `Device()`.
Expand Down
8 changes: 3 additions & 5 deletions src/python/AGENTS.md
Original file line number Diff line number Diff line change
Expand Up @@ -81,12 +81,10 @@ scheduling fields, and write only the resulting JSON to stdout. Extend

## Bundled Runtime Data

The SCEPTRE app ships configuration tables, SunSpec XML models, and the
MyDesigner template tree; Ignition ships a Jython 2.7 template tree; SCORCH
ships scripts and binary payloads. Treat all of it as runtime package data.
The SCEPTRE app ships configuration tables and the MyDesigner template tree;
Ignition ships a Jython 2.7 template tree; SCORCH ships scripts and binary
payloads. Treat all of it as runtime package data.

- Leave `phenix_apps/apps/sceptre/protocols/sunspec/` exactly as-is. It is
excluded from Ruff and codespell for that reason.
- `phenix_apps/apps/ignition/templates/` is Jython 2.7 and is excluded from
Ruff and vulture. Do not modernize it to Python 3 syntax.
- Do not reformat, regenerate, or replace bundled third-party or binary assets
Expand Down
3 changes: 1 addition & 2 deletions src/python/phenix_apps/apps/sceptre/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@
The **SCEPTRE app** builds industrial control system (ICS/SCADA) experiments. A
simulation *provider* (PowerWorld, PyPower, Simulink, RTDS, ...) models a
physical process; *field devices* expose that process over real industrial
protocols (DNP3, Modbus, BACnet, IEC 60870-5-104, SunSpec); and an *OPC server*,
protocols (DNP3, Modbus, BACnet, IEC 60870-5-104); and an *OPC server*,
*SCADA server*, *HMIs*, *engineer workstations* and a *historian* sit on top of
them the way they would in a real plant.

Expand Down Expand Up @@ -367,5 +367,4 @@ Pre-existing, and pinned by a test rather than silently carried.
| **The ELK restart script points at one provider** | `sceptre_provider_restart.py` is rendered with the last provider's address, so the others cannot be restarted from ELK. Visible in the golden fixture, which has four providers. |
| **Inconsistent mgmt-vlan filtering** | The OPC/SCADA/historian code compares `vlan != "mgmt"` case-sensitively; the field device code lowercases first. `MGMT` is therefore excluded in one and not the other. Both now go through `hosts.non_mgmt(case_sensitive=...)`, so the split is visible at each call site and pinned by `test_hosts.py`. |
| **`Register.addresses` is global state** | Class-level mutable state reset per `FieldDeviceConfig`, so register numbering is order-dependent. Tests reset it via an autouse fixture. |
| **SunSpec register maps are unreachable** | `SunSpecDevice.Register.mappings` is keyed `PowerDistribution`/`PowerTransmission`, but a device carries the lowercase infrastructure name, so any inverter on the `sunspec` protocol raises `KeyError`. Pinned in `infrastructures_golden.txt`. |
| **`reg_config` is never populated** | Nothing in the app builds a manual register map, so the `reg_config` branch in `Register.__init__` is unreachable. Only `protocols/*` remains in the ruff per-file-ignores; everything else in the app is fully linted. |
Original file line number Diff line number Diff line change
Expand Up @@ -6,8 +6,9 @@
# range the register range for the whole infrastructure, which OpcConfig
# reads. A device type repeats it only when it differs.
# devices device type -> the fields it exposes per field type. An
# inverter's analog-read-write list holds SunSpec model numbers
# rather than field names.
# inverter's analog-read-write list still holds the SunSpec model
# numbers it was built from when SunSpec was supported; on other
# protocols they become registers named after the numbers.
#
# Adding a device type here is enough for validation to accept it and for
# create_device to build it; tests/test_infrastructures.py pins every
Expand Down
11 changes: 0 additions & 11 deletions src/python/phenix_apps/apps/sceptre/configs/registers.py
Original file line number Diff line number Diff line change
Expand Up @@ -7,8 +7,6 @@

from typing import ClassVar

import phenix_apps.apps.sceptre.protocols.sunspec as sunspec


class Device:
def __init__(
Expand Down Expand Up @@ -36,15 +34,6 @@ def __init__(

def __generate_register_list(self) -> None:
for field_type, fields in self.fields.items():
if self.protocol == "sunspec":
# Only an inverter has a SunSpec map, and its models live in the
# analog-read-write list.
if self.device_type == "inverter" and field_type == "analog-read-write":
sunspec.SunSpecDevice(
self.infrastructure, self.device_name, self.registers
).generate_registers(fields)
continue

self.registers += [
Register(
self.device_name,
Expand Down
35 changes: 8 additions & 27 deletions src/python/phenix_apps/apps/sceptre/field_devices.py
Original file line number Diff line number Diff line change
Expand Up @@ -27,7 +27,6 @@
"bacnet": "47808-local",
"goose": "61850",
"iec60870-5-104": "2404-local",
"sunspec": "502-local",
}

# Reported as 0 when unused: dashboards expect the key to exist.
Expand Down Expand Up @@ -139,34 +138,16 @@ def fd_servers(self) -> None:

config_file = fd_directory / "config.xml"

sceptre_type = "field-device"
if "sunspec" in parsed.devices_by_protocol:
sceptre_type = "sunspec"

if sceptre_type == "sunspec":
self.render(
"sunspec.mako",
config_file,
name=fd_config.name,
cycle_time=fd_cycle_time,
infra=fd_config.infrastructure_name,
device=fd_config.protocols[0].devices[0],
ipaddr=fd_config.ipaddr,
publish_endpoint=fd_config.publish_endpoint,
server_endpoint=fd_config.server_endpoint,
devname=fd_config.protocols[0].devices[0].registers[0].devname,
)
else:
self.render(
"fd_server.mako",
config_file,
fd_config=fd_config,
logic=fd_logic,
cycle_time=fd_cycle_time,
)
self.render(
"fd_server.mako",
config_file,
fd_config=fd_config,
logic=fd_logic,
cycle_time=fd_cycle_time,
)

self.app.render_sceptre_start(
fd_, name=sceptre_type, needrestart=needrestart
fd_, name="field-device", needrestart=needrestart
)

# What the ELK dashboards read: which ports this device listens on.
Expand Down
1 change: 0 additions & 1 deletion src/python/phenix_apps/apps/sceptre/metadata.py
Original file line number Diff line number Diff line change
Expand Up @@ -88,7 +88,6 @@ class SceptreMetadataParser:
"dnp3",
"dnp3-serial",
"modbus",
"sunspec",
"iec60870-5-104",
]

Expand Down
Empty file.