Repository navigation
Conversation
BuEM's v6-draft request schema requires building_type, country and
A_ref on every building, residential_units for MFH and AB, and rejects
household inputs on service buildings. The serialiser met none of
that: an MFH or AB run (the default building type) was rejected for
the missing dwelling count, and the Office, School, Retail and Hotel
labels were sent as-is instead of BuEM's lowercase codes.
- The building types are the four residential codes and BuEM's eight
service types. Retail, which BuEM has no type for, is gone.
- Residential buildings send residential_units, num_persons,
archetype, region_code, cooking_carrier, include_dhw and the
equipment overrides. The serialiser throws when an MFH or AB has no
dwelling count, and a run reports it instead of sending.
- Service buildings send capacity and none of the household inputs,
and request no hot water or cooking profile.
- setback_profile is sent for every building.
- properties.buem.outputs selects each load profile as none, summary
or series. The default is series for all five, since BuEM returns
only an annual summary for an omitted profile and the overview
charts need the hourly values. With heating and cooling both none
the building carries no envelope.
- A wall element with bTransmission set sends b_transmission, which
BuEM reads as a party wall at 0.
- neighbour_status and n_storeys are no longer sent; v6-draft marks
both deprecated and BuEM ignores them. The attached-neighbours
picker is removed. A reopened stored building keeps its total floor
area but shows the default storey count.
- The response mapping accepts a result with no heating, cooling or
electricity profile.
- TABULA's n_Apartment prefills residential_units when a building
loads without one, and on every hand-edited classification.
Breaking for hosts: BuemBuildingRunRequest gains outputs, which the
transport must forward as properties.buem.outputs, and toBuem returns
{ building, outputs, solver }. Both need a buem-gateway that accepts
the v6-draft schema.
Payloads for an SFH, an MFH with every household input, an office and
an AB with no thermal outputs validate against that schema; the
previous serialiser's MFH, AB and office payloads did not.
The building editor gains three sections for the inputs the v6-draft serialiser now sends. - Occupancy: dwellings (required for MFH and AB, prefilled from TABULA), occupants per dwelling, household type, Dutch region code, cooking carrier, whether hot water is reported, and heating setback. A service building shows capacity and setback only. - Results to compute: each of the five load profiles off, annual or hourly. Service buildings do not offer hot water or cooking gas. With heating and cooling off the section says surfaces and weather go unused. - Appliances (expert mode, residential only): each of BuEM's appliances set to default, yes or no, and a TV count of 0 to 3 mapped onto tv_1 to tv_3. For MFH and AB it says every dwelling gets the same appliances. A section the building type hides closes when the type changes.
BuEM treats a wall with b_transmission 0 as a party wall, with no heat loss through it and no synthesised windows. The surface editor gains a checkbox on walls that sets bTransmission to 0, which the serialiser sends as b_transmission. It replaces the attached-neighbours picker, whose neighbour_status field BuEM ignores.
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Brings the configurator's BuEM payload and building editor in line with the v6-draft request schema, so a user can set everything BuEM reads.
Breaking for hosts
BuemBuildingRunRequestgainsoutputs. A transport must forward it asproperties.buem.outputs; one that drops it gets annual summaries only, with no hourly profile to chart.toBuemreturns{ building, outputs, solver }.outputsblock.n_storeysorneighbour_status. Reopened, it keeps its total floor area and shows the default storey count.What changes
6c7c6b8): building types are the four residential codes plus BuEM's eight service types (Retail is gone). MFH and AB sendresidential_unitsand the serialiser throws without it; a run reports this instead of sending. Residential buildings send occupancy and appliance overrides; service buildings sendcapacityand no household inputs.outputsis sent, defaulting to hourly for every profile; with heating and cooling off the building carries no envelope. Walls withbTransmissionsendb_transmission. TABULAn_Apartmentprefills the dwelling count. The response mapping accepts a result with no heating, cooling or electricity profile.9c5b576): Occupancy and Results to compute sections, and an Appliances section in expert mode for residential buildings.b5cd904): a "Shared with a neighbouring building" checkbox on walls replaces the attached-neighbours picker.Checks
npm test107/107. The new and changed tests inbuemAdapter.household.test.tsandbuemRun.test.tsfail onmain(11 failures) and pass here.npm run typecheckclean,npm run build:libsucceeds.outputs. Onmainthe MFH, AB and office payloads fail it.Not run: a live BuEM simulation.