Skip to content

Numeric guards leak OverflowError for very large inputs #739

Closed

Description

@kstonekuan

Problem

The shared numeric guards can raise an unlabelled OverflowError while checking caller input. On main at 7d202bc:

from fractions import Fraction
from hflow.batching import plan_batches
from hflow.transform import TransformConfig

TransformConfig(gop_seconds=10**400)
# OverflowError: int too large to convert to float

plan_batches({'item': 1}, batch_count=1, stagger_interval_s=Fraction(10**400, 1))
# OverflowError: integer division result too large for a float

src/hflow/_field_guards.py:67 and :91 pass these values to math.isfinite, which converts them to float. Other invalid values already raise ValueError naming the field.

Done when

  • Values too large for the floating-point check raise a field-specific ValueError at both public entry points, including a large integer and a large Fraction.
  • Valid integer, float, and Fraction inputs keep their existing behavior, including exact fractional batch delays.
  • Extend the boundary tests in tests/test_batching.py:129 and the transform settings tests. The existing guards in src/hflow/_field_guards.py show the error-message pattern.

Validation

uv sync --locked
uv run ruff check --fix
uv run ruff format
uv run ty check
uv run pytest -q

Activity

  1. yoveneim commented on Oct 27, 2026

    @yoveneim
    Contributor

    Hi , I would like to work on this one .

  2. kstonekuan commented on Oct 27, 2026

    @kstonekuan
    ContributorAuthor

    thanks, assigned

  3. added a commit that references this issue on Nov 5, 2026
    0369048
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment