fix(safety): keep filter pump running on combined connectivity/sensor faults
Port of #205 onto the multicore architecture.
Before, any two of WiFi loss, NTP loss and a sensor fault escalated to
CRITICAL and switched all relays off. A WiFi outage plus a faulty probe
therefore stopped the filter pump, which is the opposite of what water
hygiene needs. Only a forced (boot-loop) safe mode or persistently low
heap now leads to CRITICAL; the level rules move into the pure
DegradationPolicy.hpp and get native tests. Safety-model and
state-persistence docs follow the new policy.