This is a Python library to control the RWC5020x LoRa Tester remotely through either the serial port (RS232) or the Ethernet port.

  • Supported analyzers (current generation):

    RWC5020B RWC5020M
    RWC5020B Tester RWC5020M Tester
  • Supported analyzer (previous generation):

    RWC5020A
    RWC5020A Tester

Requirements

API Setup

Python API Setup

  • To access RWC5020x tester using Python Library, please follow the setup shown in the diagram.

How to install the package

  1. Clone the repository from github

  2. Open a terminal window and change directory to {path_to_repository}/rwc-python-api.

  3. To install the library in your local Python setup, enter the command

    python setup.py install

How to use the package

Create a Python file and import the class library from package:

from rwclib.cRWC5020x import RWCTesterApi

Create a class object and pass serial port or ethernet port & ip address as constructor parameter

# ---Serial Communication---
rwc = RWCTesterApi('COM5') #windows
(or)
rwc = RWCTesterApi('/dev/ttyUSB0') #Linux

# ---Ethernet Communication---
rwc = RWCTesterApi('5001', '192.168.0.33')

Access the class methods using instantiated object

rwc.query_identification()

To know more about class methods, please see the code documentation in the following location in this repository: ./doc/build/html/index.html

Example scripts showing how to use the library can be found in the examples directory.

Support

The Python library supports RWC5020x firmware from v1.150 on. v1.0.5 to v1.1.0 were tested with an RWC5020B running firmware v1.500; v1.2.0 was tested with firmware v1.500 and v1.604. There is no manual for firmware later than v1.500; commands for later firmware come from the firmware release notes and from tests on the tester.

The library logs each command and response through Python's logging module, under the logger rwclib.cRWCSerialSetup. To see them, configure logging in your script, for example logging.basicConfig(level=logging.INFO).

Release History

  • v1.2.0 has the following changes:

    • Part of #18: firmware v1.604.
    • Firmware v1.520 separated LoRa CRC from the coding rate. New nst_tx/rx/mfg_set/getcrc() and nst_rx_set/getimplicitcrc(). On v1.520 and later, nst_tx_setcr(), nst_mfg_setcr() and nst_rx_setimplicitcr() raise for NO_CRC, and nst_rx_setcr() raises for any coding rate: on v1.604, CONF:NST:RX:CR takes ON or OFF and sets the RX CRC.
    • SF5 and SF6 for NST TX, RX and MFG on v1.520 and later; 16-CH for rf_setedtmultichannel() on v1.510 and later (it needs the tester's 16-channel option); protocol_set/getrelaymode() on v1.600 and later; query_incertoptinfo().
    • link_set/getadrchmask_optdr() and query_ilcertoptinfo() raise on v1.604, which answers NAK; the release notes don't say when or why these went.
    • link_setfopts() raises unless the value's length matches FOPTS_SIZE. The tester accepts a shorter value and keeps the old bytes after it; a hex string passed without 0x is read as decimal and is usually shorter.
  • v1.1.0 has the following changes:

    • Part of #18: methods for commands in the v1.500 manual that the library lacked: EDT channel plan, RX AGC, NST implicit header, coding rate and payload size, NST frame-count averaging, FOpts user payload and its size, uplink and downlink dwell time, general application key, sensitivity PER result by index, and the 64-channel and AU, RU, IL and EU433 certification option queries.
    • On firmware v1.500, link_getfoptspayload() gets NAK even after link_setfoptspayload() has set a payload. The dwell-time getters return 1 for 400ms and 0 for NO_LIMIT.
  • v1.0.9 has the following changes:

    • Part of #18: sensitivity_setrx2frequency() works (it was a stub); uplink and downlink channel methods take an optional channel number; firmware version checks use numeric ranges instead of lists, and fail with a clear error if the tester doesn't report its version.
  • v1.0.8 has the following changes:

    • Part of #18: region names AU_915, KR_920 and IN_865 (old names still accepted); ICA operator; ranges for target PER, power Y-axis minimum, fragment padding, MFG packet interval and TX power; payload setters take bytes or hex strings starting with 0x, and keep leading zero bytes; per-channel power for channels above 7.
    • Payload and sync-word setters read a plain string as decimal, as v1.0.4 did. v1.0.5 to v1.0.7 read a plain string passed to nst_tx_setpayload() or a sync-word setter as hex; write hex as '0x...' or pass bytes.
  • v1.0.7 has the following changes:

    • Part of #18: link_getmacsendresult() sends MAC_SEND_RESULT; link_set/getadrchmask_optdr() send ADR_CH_MASK_OPT <MAC_NUM> on firmware v1.200 and later; nst_rx_settxpolarity() sends RX_POLARITY; nst_tx_getmode() reads MODULATION. Methods for commands deleted in firmware v1.32 and v1.33 raise on that firmware and later.
    • Offline tests in tests/test_commands.py.
  • v1.0.6 has the following changes:

    • All six RF frequency setters send the frequency to 1 Hz. v1.0.5 kept only 6 significant digits in rf_setfrequency() and rf_settxfrequency() (865.0625 MHz went out as 865.062), and the other four truncated to whole MHz.
    • Over Ethernet, transceive() discards replies that arrive after a timeout, so they no longer shift every later reply by one. The timeout is 15 s; CONF:RF:RX_FREQ takes about 5.5 s.
  • v1.0.5 has the following changes:

    • Fix #14: commands that failed on firmware v1.500. Data-rate setters accept any firmware from v1.170 on; frequency setters accept fractional MHz; nst_tx_setpayloadsize() sends the NST command; nst_tx_setpayload() and the sync-word setters take bytes or hex strings; NST getters use READ: queries.
    • Fix #13: the library no longer configures logging or writes ../logs/rwcapi.log; setup.py requires pyserial.
  • v1.0.4 has the following changes:

    • Fix #6: Added new remote commands for the latest firmware v1.310
  • v1.0.3.10 includes the following changes:

    • Fix #2: Updated latest remote commands and added backward compatibility to python library for support of RWC5020x firmware from v1.150 to v1.305.