Source-Generated NodeManagers

This guide explains how to use the OPC UA stack source generator to emit a ready-to-host AsyncCustomNodeManager for an information model design XML, and how to wire callbacks (read/write/method/lifecycle) using the fluent INodeManagerBuilder API. The combination is designed for single-file, NativeAOT-friendly servers — see samples/MinimalBoilerServer for the canonical sample.

What the generator produces

The base source generator already emits, for each model design:

  • Add{Ns}(NodeStateCollection, ISystemContext) — populates a node collection.
  • Add{Ns}(INodeStateFactoryBuilder) — registers strongly-typed activators.
  • Add{Ns}DataTypes(IEncodeableFactoryBuilder) — registers encodeables.

When ModelSourceGeneratorGenerateNodeManager=true is set or a class is annotated with [Opc.Ua.Server.Fluent.NodeManagerAttribute], the generator additionally emits, in either the {ModelNamespace} namespace (legacy MSBuild mode) or the user class's namespace (attribute mode):

  • public partial class {Ns}NodeManager : AsyncCustomNodeManager (legacy) or public partial class {UserClass} : AsyncCustomNodeManager (attribute)
    • Constructor (IServerInternal, ApplicationConfiguration).
    • Pre-registers the model namespace URI.
    • LoadPredefinedNodesAsync returns new NodeStateCollection().Add{Ns}(context) wrapped in a ValueTask<NodeStateCollection>.
    • CreateAddressSpaceAsync awaits base.CreateAddressSpaceAsync, then builds a fluent INodeManagerBuilder, invokes Configure(builder), calls builder.Seal(), and replays NotifyNodeAdded for every predefined node so per-node lifecycle hooks fire deterministically.
    • AddPredefinedNodeAsync / RemovePredefinedNodeAsync overrides forward to base and then dispatch the lifecycle notification.
    • OnMonitoredItemCreated (still synchronous on the base) dispatches the per-node hook.
    • Declares partial void Configure(INodeManagerBuilder builder); for user wiring.
  • public class {Ns}NodeManagerFactory : IAsyncNodeManagerFactory
    • Returns the namespace URI in NamespacesUris.
    • CreateAsync(IServerInternal, ApplicationConfiguration, CancellationToken) returns a ValueTask<IAsyncNodeManager> containing a new manager instance.
    • Both members are virtual so consumers can subclass to add a second namespace or swap in a manager subclass.

AddNodeManager on StandardServer has overloads for both INodeManagerFactory and IAsyncNodeManagerFactory; the generated async factory binds to the latter automatically.

Opting in

Add the generator analyzer to your project (this is what OPCFoundation.Opc.Ua.SourceGeneration.props is for) and choose one of the two opt-in modes:

Per-class opt-in via [NodeManager] (recommended)

Annotate the user-authored partial class that should host the generated manager:

using Opc.Ua.Server.Fluent;

namespace MyCompany.MyServer;

[NodeManager]
public partial class MyDeviceNodeManager
{
    partial void Configure(INodeManagerBuilder builder)
    {
        // wire your callbacks here
    }
}

The generator emits a sibling partial class MyDeviceNodeManager : AsyncCustomNodeManager and a MyDeviceNodeManagerFactory (implementing IAsyncNodeManagerFactory) in the same namespace as the user class. No MSBuild flag is required.

When a project carries multiple model designs, disambiguate which design the attribute targets via either:

[NodeManager(NamespaceUri = "http://opcfoundation.org/UA/Boiler/")]

or by file stem:

[NodeManager(Design = "BoilerDesign")]

Set GenerateFactory = false to suppress factory emission when you want to ship a hand-written IAsyncNodeManagerFactory.

Project-wide opt-in via MSBuild property (legacy)

If you prefer a generator-derived class identity ({Prefix}NodeManager / {Prefix}NodeManagerFactory) without authoring a stub partial, set the opt-in property:

<PropertyGroup>
  <ModelSourceGeneratorGenerateNodeManager>true</ModelSourceGeneratorGenerateNodeManager>
</PropertyGroup>

<ItemGroup>
  <AdditionalFiles Include="Generated\MyModelDesign.xml" />
  <AdditionalFiles Include="Generated\MyModelDesign.csv" />
</ItemGroup>

This emits {Prefix}NodeManager + {Prefix}NodeManagerFactory for every design in the project. Wire callbacks by adding a sibling partial class {Prefix}NodeManager that implements Configure.

Without either opt-in, only the existing Add{Ns}* extensions are emitted — hand-written AsyncCustomNodeManager (or legacy CustomNodeManager2) subclasses keep working unchanged.

Wiring callbacks: the Configure partial

Author a sibling partial that fills in Configure:

namespace MyModel;

public partial class MyModelNodeManager
{
    partial void Configure(INodeManagerBuilder builder)
    {
        builder
            .Node("Boilers/Boiler #1/Drum1001/LevelIndicator/Output")
            .OnRead(MyReadHandler);

        // Resolve a singleton instance by its TypeDefinitionId — stable
        // across deployments and independent of where the instance sits
        // in the tree. Ideal for well-known types like
        // HistoryServerCapabilities or a single BoilerType instance.
        builder
            .NodeFromTypeId(ExpandedNodeId.ToNodeId(
                MyModel.ObjectTypeIds.BoilerType, Server.NamespaceUris))
            .OnNodeAdded((ctx, node) => /* ... */);

        // For multi-instance types, disambiguate with a BrowseName:
        builder
            .NodeFromTypeId(
                ExpandedNodeId.ToNodeId(MyModel.ObjectTypeIds.BoilerType, Server.NamespaceUris),
                new QualifiedName("Boiler #2", nsIndex))
            .OnRead(MyReadHandler);
    }
}

Path syntax is /-separated BrowseNames, rooted at the model namespace's predefined nodes. Optional ns=N; prefix lets you target a different namespace.

Addressing modes

Method Resolves by Use when
Node(string path) BrowseName path Deterministic tree layout, multiple siblings
Node(NodeId id) / Node<TState>(NodeId id) Absolute NodeId You own the id (e.g. generated Variables.*)
NodeFromTypeId(NodeId typeId) / NodeFromTypeId<TState>(NodeId typeId) BaseInstanceState.TypeDefinitionId Singleton instance of a well-known type
NodeFromTypeId(NodeId typeId, QualifiedName browseName) TypeDefinitionId + BrowseName Multi-instance types — pick one

NodeFromTypeId walks every predefined node owned by this manager (and their sub-trees) at Configure-time. Error matrix:

  • BadNodeIdInvalidtypeId is null or IsNull.
  • BadNodeIdUnknown — no instance carries that TypeDefinitionId, or the optional browseName disambiguator finds no match.
  • BadBrowseNameDuplicated — more than one candidate and no disambiguator was supplied (or multiple candidates share the same browseName).
  • BadTypeMismatch — typed overload's TState cast fails.

The builder exposes:

Method Wires
OnRead / OnReadAsync BaseVariableState.OnReadValue
OnWrite / OnWriteAsync BaseVariableState.OnWriteValue
OnCall / OnCallAsync MethodState.OnCallMethod*
OnNodeAdded / OnNodeRemoved Lifecycle dispatch from NotifyNodeAdded
OnEvent, OnConditionRefresh, OnHistoryRead, OnHistoryUpdate, OnMonitoredItemCreated Manager-level dispatch keyed by NodeId

INodeManagerBuilder.NodeManager is typed as IAsyncNodeManager. Use builder.NodeManager.SyncNodeManager to obtain the synchronous INodeManager facade for legacy interop, or cast it to your concrete manager type if you need direct access.

All resolution happens once during CreateAddressSpaceAsync, against the in-memory predefined-node tree. There is no reflection, no Activator.CreateInstance, no Expression.Compile — the whole pipeline is NativeAOT-safe.

Typed model-traversal — the Configure(I{Manager}NodeManagerBuilder) partial

Alongside the string/NodeId/TypeId addressing surface above, the generator emits a second Configure partial whose builder parameter exposes one IntelliSense-aware accessor per predefined instance, child, variable and method in the model. Every wiring site becomes a chain of properties — typos are compile-time errors, not startup-time ServiceResultExceptions.

public partial class BoilerNodeManager
{
    // Untyped Configure remains available for nodes outside the model
    // (e.g. dynamic instances, foreign-namespace nodes, or just to keep
    // hand-written wiring side-by-side with typed wiring).
    partial void Configure(INodeManagerBuilder builder)
    {
        builder
            .Node("Boilers/Boiler #1/DrumX001/LIX001/Output")
            .OnRead(GenerateDrumLevel);
    }

    // Typed Configure: every accessor below is a generated property
    // resolved against the model. The compiler enforces both the path
    // shape AND the value type of every leaf.
    partial void Configure(IBoilerNodeManagerBuilder builder)
    {
        // Variable: typed Func<double> handler — the generator removed
        // the ref-Variant boilerplate.
        builder.Boilers.Boiler__1.LCX001.Measurement
            .OnRead(GenerateLevelMeasurement);

        // Variable, async: routes through BaseVariableState.ReadAttributeAsync
        // outside the lock so the lambda may freely await.
        builder.Boilers.Boiler__1.PipeX002.FTX002.Output
            .OnRead(GenerateOutputFlowAsync);

        // Method, async: typed OnCall(Func<CancellationToken,ValueTask>)
        // overload. Bind sync Action variants the same way.
        builder.Boilers.Boiler__1.Simulation.Halt
            .OnCall(HaltSimulationAsync);
    }
}

Both partials are optional and both run; wiring the same node from both is illegal and throws at startup. Choose whichever shape best fits each call site — typed for everything declared in the model, untyped for everything else.

What the generator emits per model

For a model with N ObjectTypes and M predefined instances/children the generator emits, into a single {Manager}.FluentBuilders.g.cs:

  • internal interface I{Manager}NodeManagerBuilder : INodeManagerBuilder — one accessor per top-level predefined instance.
  • internal sealed class {Manager}NodeManagerTypedBuilder — proxy that forwards INodeManagerBuilder members to the runtime builder while surfacing the typed accessors.
  • One internal sealed class per instance node — whose properties map to typed IVariableBuilder<TValue>, child wrapper instances, and method wrappers.
  • One internal sealed class per method — exposing typed OnCall(...) overloads bound to the method's declared arguments (the generator handles Variant.TryGetValue unpacking and Variant.From<T> boxing — see Methods with arguments). A method with inputs but no output binds to OnCall(Action<TIn…>); a method with neither inputs nor outputs keeps the argument-less OnCall(Action) / OnCall(Func<CancellationToken, ValueTask>) overloads.

All emitted types are internal sealed because Configure is a private partial — the surface never escapes the assembly. Child accessors resolve namespace indices lazily through ISystemContext.NamespaceUris.GetIndexOrAppend(...) so the wrappers work regardless of the namespace-table order at runtime.

Methods with arguments — typed OnCall overloads

When a model method declares input or output arguments the generator emits typed OnCall overloads that bind directly to the user handler's parameters and return value. Inputs are unboxed via Variant.TryGetValue<T>(out T), the boxed result is written back through Variant.From<T>(value), and BadInvalidArgument / BadArgumentsMissing is returned when the wire shape does not match the declared signature — none of which the user has to spell out.

Two overloads are emitted per method, shaped by the declared arguments:

  • Inputs and outputsOnCall(Func<TIn1, …, TResult> handler) (synchronous dispatch through MethodState.OnCallMethod2) and OnCall(Func<TIn1, …, CancellationToken, ValueTask<TResult>> handler) (async dispatch through MethodState.OnCallMethod2Async, awaited inside AsyncCustomNodeManager.CallAsync so the lambda may freely await).
  • Inputs but no output (a void-returning action) → OnCall(Action<TIn1, …> handler) and OnCall(Func<TIn1, …, CancellationToken, ValueTask> handler). The inputs are still unpacked via Variant.TryGetValue<T>, so builder.X.SetOutputVal.OnCall((float v) => …) binds directly to the argument.
  • No inputs and no output → the argument-less OnCall(Action) / OnCall(Func<CancellationToken, ValueTask>) overloads.

Methods with multiple output arguments are bound to a ValueTuple return — slot i is written from __r.Item{i+1}.

The declared arguments are resolved from the method itself and, when the method carries none of its own, from its method declaration / method type. This means instance methods imported from a NodeSet2 (whose InputArguments/OutputArguments live on the referenced declaration) get the same typed OnCall overloads as methods authored in a ModelDesign.

[NodeManager(NamespaceUri = "http://opcfoundation.org/UA/Calc/")]
public partial class CalcNodeManager
{
    partial void Configure(ICalcNodeManagerBuilder builder)
    {
        // Sync int+int → int. The generator unpacks each Variant
        // through Variant.TryGetValue<int> and boxes the result back
        // through Variant.From<int>.
        builder.Calculator.Add
            .OnCall((int a, int b) => a + b);

        // Async double+double → double. The CancellationToken is
        // forwarded by AsyncCustomNodeManager.CallAsync so the
        // handler may freely await and honour cancellation.
        builder.Calculator.Multiply
            .OnCall(async (double x, double y, CancellationToken ct) =>
            {
                await Task.Yield();
                ct.ThrowIfCancellationRequested();
                return x * y;
            });

        // Sync string+string → string. Reference-typed inputs and
        // return values use the same Variant.TryGetValue / Variant.From
        // path; the handler can null-coalesce safely because a missing
        // input is reported as BadInvalidArgument before the lambda
        // ever runs.
        builder.Calculator.Concat
            .OnCall((string left, string right) =>
                (left ?? string.Empty) + (right ?? string.Empty));
    }
}

The end-to-end sample lives in samples/MinimalCalcServer/ (model in Model/Calc.xml, wiring in CalcNodeManager.Configure.cs). The companion AOT round-trip tests in tests/Opc.Ua.Aot.Tests/CalculatorNodeManagerAotTests.cs exercise each shape over a real Session.CallAsync(...).

Event sources — typed Publish<TEvent> on notifier wrappers

Beyond reads, writes and method calls, the fluent API lets callers register an IAsyncEnumerable<TEvent> against any notifier object so events flow into the standard NodeState.ReportEvent path automatically. The runtime owns the entire lifecycle: it starts the iterator the first time a client subscribes to events on the notifier (or any ancestor that walks via inverse HasNotifier / HasEventSource references), cancels it when the last interested monitored item disappears, and disposes it on manager teardown.

Generated managers derive from Opc.Ua.Server.Fluent.FluentNodeManagerBase out of the box, so wiring is one call:

partial void Configure(IBoilerNodeManagerBuilder builder)
{
    // The DrumX001 wrapper exposes Publish<TEvent> because the model
    // declares EventNotifier=SubscribeToEvents on the node. Lazy by
    // default — the iterator only runs while a client is monitoring.
    builder.Boilers.Boiler__1.DrumX001
        .Publish<BaseEventState>(GenerateDrumHeartbeatAsync);
}

private async IAsyncEnumerable<BaseEventState> GenerateDrumHeartbeatAsync(
    BaseObjectState notifier,
    ISystemContext context,
    [EnumeratorCancellation] CancellationToken cancellationToken)
{
    while (!cancellationToken.IsCancellationRequested)
    {
        try
        {
            await Task.Delay(TimeSpan.FromMilliseconds(500), cancellationToken)
                .ConfigureAwait(false);
        }
        catch (OperationCanceledException) { yield break; }

        var ev = new BaseEventState(parent: notifier);
        ev.Severity = PropertyState<ushort>.With<VariantBuilder>(
            ev, (ushort)EventSeverity.Medium);
        ev.Message = PropertyState<LocalizedText>.With<VariantBuilder>(
            ev, new LocalizedText("Drum heartbeat"));
        yield return ev;
    }
}

The runtime auto-populates EventId, EventType, SourceNode, SourceName (browse name of the notifier), Time, ReceiveTime, Severity (Medium when 0) and Message (empty LocalizedText when unset) on the way out, so the iterator only sets the user-meaningful fields.

Where the typed overload appears

The generator emits Publish<TEvent> on a wrapper only when the underlying node qualifies as an event source:

  • ObjectDesign.SupportsEvents == true (i.e. the model declares EventNotifier=SubscribeToEvents, HasNotifier, or HasEventSource), or
  • The node has a forward GeneratesEvent / AlwaysGeneratesEvent reference.

TEvent is constrained to BaseEventState — pass any subtype that fits the model's event hierarchy. For nodes outside the model, or hand-written managers, the same Publish<TNotifier, TEvent> extension is available directly on INodeBuilder<TNotifier> where TNotifier : BaseObjectState.

Two registration shapes

// Direct stream — registry uses the same instance for every activation.
builder.Boilers.Boiler__1.DrumX001
    .Publish<BaseEventState>(channel.Reader.ReadAllAsync(default));

// Factory — registry calls the factory each time a client subscribes,
// so the iterator can capture the live notifier / context / token.
builder.Boilers.Boiler__1.DrumX001
    .Publish<BaseEventState>(
        (notifier, context, ct) => GenerateAsync(notifier, context, ct));

Tuning lifecycle with EventPublishOptions

builder.Boilers.Boiler__1.DrumX001
    .Publish<BaseEventState>(GenerateDrumHeartbeatAsync,
        new EventPublishOptions
        {
            // Keep iterator running even with no monitored items.
            AlwaysOn               = false,

            // Skip default population of EventId / EventType / Time /
            // ReceiveTime / SourceNode / SourceName / Severity / Message.
            SkipDefaultPopulation  = false,

            // Register the notifier as a server-wide root notifier so
            // clients can monitor events on the Server object itself.
            RegisterAsRootNotifier = true,

            // Bound how long the registry waits for the iterator to
            // honour cancellation on deactivation.
            CancellationTimeout    = TimeSpan.FromSeconds(5),

            // Optional fault-handler invoked when the iterator throws.
            OnError = (notifier, exception, context) => { /* log */ }
        });

Hand-written node managers

Managers that don't use the source generator can opt in by deriving from Opc.Ua.Server.Fluent.FluentNodeManagerBase and calling AttachToBuilder(builder) from inside their address-space-build callback. Once attached, all Publish extensions resolve against the manager's registry exactly as for generated managers.

The end-to-end sample lives in samples/MinimalBoilerServer/BoilerNodeManager.Configure.cs (wiring GenerateDrumHeartbeatAsync on the drum). The companion AOT round-trip test in tests/Opc.Ua.Aot.Tests/PublishedEventsAotTests.cs subscribes a real client MonitoredItem with an EventFilter and asserts the heartbeats arrive end-to-end under NativeAOT constraints (no JIT, no reflection).

Single-file Program.cs — what it looks like

The shipping services.AddOpcUa().AddServer(...) extension wires the server into the .NET Generic Host: configuration, certificate check, ApplicationInstance lifetime and Ctrl+C/SIGTERM handling are all owned by the host. User code stays at ~12 lines.

using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Hosting;
using Microsoft.Extensions.Logging;

HostApplicationBuilder builder = Host.CreateApplicationBuilder(args);
builder.Logging.AddConsole();

builder.Services
    .AddOpcUa()
    .AddServer(o =>
    {
        o.ApplicationName = "MyServer";
        o.ApplicationUri  = "urn:localhost:MyServer";
        o.ProductUri      = "uri:opcfoundation.org:MyServer";
        o.AutoAcceptUntrustedCertificates = true;
        o.EndpointUrls.Add("opc.tcp://localhost:51210/MyServer");
    })
    .AddNodeManager<MyModel.MyModelNodeManagerFactory>();

await builder.Build().RunAsync();

AddOpcUa() registers a ServiceProviderTelemetryContext that adapts the host's ILoggerFactory to ITelemetryContext — no separate logging pipeline is required. IOpcUaServerBuilder.AddNodeManager<T>() registers an IAsyncNodeManagerFactory; use AddSyncNodeManager<T>() for the legacy INodeManagerFactory. For advanced configuration (custom security policies, additional builder calls), set OpcUaServerOptions.ConfigureBuilder.

That's the whole server. The Boiler version is in samples/MinimalBoilerServer/Program.cs.

Multi-namespace and manager-swap subclassing

Because the generated factory members are virtual, you can extend without forking:

public sealed class MyExtendedFactory : MyModel.MyModelNodeManagerFactory
{
    public override ArrayOf<string> NamespacesUris
    {
        get
        {
            var ns = base.NamespacesUris;
            ns.Add("urn:my:second:namespace");
            return ns;
        }
    }

    public override ValueTask<IAsyncNodeManager> CreateAsync(
        IServerInternal server,
        ApplicationConfiguration cfg,
        CancellationToken cancellationToken = default)
        => new(new MyExtendedNodeManager(server, cfg));
}

The tests/Opc.Ua.Server.Tests/Fluent/GeneratedManagerHybridTests.cs suite verifies these subclassing scenarios.

NativeAOT publishing

The project that hosts the generated manager only needs the standard AOT settings:

<PropertyGroup>
  <PublishAot>true</PublishAot>
  <InvariantGlobalization>true</InvariantGlobalization>
  <TargetFramework>net10.0</TargetFramework>
</PropertyGroup>

Use Microsoft.Extensions.Logging.Console for AOT-friendly logging (Serilog providers vary in AOT compatibility). Validate with:

dotnet publish -c Release -r win-x64

samples/MinimalBoilerServer publishes cleanly with zero AOT/trim warnings (~29 MB self-contained EXE).

Runtime NodeSet alternative

When you want to host a NodeSet2 document without any source generation — for example a companion-spec XML received from a vendor, or a model that changes more frequently than you rebuild — use AddRuntimeNodeSet instead. The runtime path loads a file or stream at server startup, imports nodes in topological dependency order, and exposes them through the same untyped INodeManagerBuilder surface as the Configure partial above. No rebuild is needed when the XML content changes; restart the server to pick up new content. See RuntimeNodeSets.md for a side-by-side comparison of the two paths.

Building richer node managers — the fluent extension surface

The Configure callback wires read/write/method/event hooks against already-loaded predefined nodes, but real-world servers also need to materialise dynamic instances, attach engineering units to measurements, build alarms, run simulation loops, populate identification properties, and compose multiple companion-spec models into a single address space. The extensions below cover those workflows. All are AOT/trim safe and follow the same return-the-same-builder chaining contract as the core INodeBuilder API.

Engineering units & EU range

IVariableBuilder<TValue>.WithEngineeringUnits and .WithEURange attach the standard EngineeringUnits and EURange property children on a BaseAnalogState variable. The extensions create the property child on demand (matching the runtime's AddEngineeringUnits / AddEURange helpers) and then set the Value attribute.

builder.Variable<double>("Pumps/Pump #1/Operational/Measurements/FluidTemperature")
       .OnRead(SimulateTemperature)
       .WithEngineeringUnits(
           new EUInformation("K", "Kelvin",
               "http://www.opcfoundation.org/UA/units/un/cefact"))
       .WithEURange(min: 233.15, max: 473.15);

// Convenience: set both at once.
builder.Variable<double>("Pumps/Pump #1/Operational/Measurements/Pressure")
       .OnRead(SimulatePressure)
       .WithUnits(EUInformations.Pascal, min: 0, max: 1_000_000);

Fail-fast behaviour: calling these on a non-BaseAnalogState variable throws ServiceResultException with StatusCodes.BadTypeMismatch — analog-only properties don't apply to plain BaseDataVariableState nodes.

Bulk property initialisation

INodeBuilder.WithProperty writes the Value attribute of a property child, creating the property first when it does not already exist. Typed overloads exist for every built-in OPC UA scalar (string, int, uint, double, bool, DateTimeUtc, NodeId, LocalizedText, QualifiedName, etc.) plus a generic Variant escape hatch.

builder.Node("Pumps/Pump #1/Identification")
       .WithProperty("Manufacturer", "SimPump Corp")
       .WithProperty("Model", "PumpX-2000")
       .WithProperty("SerialNumber", "SN-001")
       .WithProperty("DeviceClass", "Pump")
       .WithProperty("ProductInstanceUri",
           "urn:simdevice:SimPump:PumpX-2000:SN-001");

Reference resolution is by browse-name only (case-sensitive, namespace-agnostic), matching the AOT-safe constraint of the rest of the fluent surface. When the child exists it is updated; when it exists but isn't a variable the call throws BadTypeMismatch.

When the child is missing, WithProperty materialises a new read-only PropertyState (data type inferred from the value) under the current node and registers it with the owning node manager. This makes the helper usable on freshly built nodes such as custom DI functional groups — not just on properties that come from a loaded model:

// "Diagnostics" is a custom functional group with no model-defined
// properties; WithProperty creates each one on the fly.
node.WithProperty("LastError", string.Empty)
    .WithProperty("ErrorCount", 0)
    .WithProperty("LastSelfTest", (DateTimeUtc)DateTime.UtcNow);

Auto-created properties are read-only by default. Grant write access with the fluent Writable() helper — either standalone on a resolved variable, or inline via the WithProperty(name, value, configure) overload that positions a builder on the new property:

node.WithProperty("LastError", Variant.From(string.Empty), p => p.Writable())
    .WithProperty("ErrorCount", 0);

// or, on an existing variable:
builder.Node("Pumps/Pump #1/Operational/SetPoint").Writable();

References & dynamic child objects

INodeBuilder.Organizes, .HasComponent, .HasProperty and the generic .AddReference(typeId, isInverse, target) add forward / inverse references on the current node. They're the foundation for OPC UA Device Integration (DI)'s FunctionalGroup pattern — group unrelated variables under a shared object via Organizes.

// Wire existing measurement variables into a custom FunctionalGroup.
builder.Node("Pumps/Pump #1/Operational/MyGroup")
       .Organizes(temperatureNodeId)
       .Organizes(pressureNodeId)
       .HasProperty(metadataNodeId);

INodeBuilder.AddObject(browseName, typeDefinitionId) synthesises a new BaseObjectState child under the current node and returns a typed builder for the new object. NodeIds follow the {parentIdentifier}_{childName} pattern used by the source generator's default factory.

// Create a custom FunctionalGroup, then attach measurements.
builder.Node("Pumps/Pump #1")
       .AddObject(new QualifiedName("CustomMetrics", pumpsNs))
       .Organizes(t1).Organizes(t2);

Newly created objects are reachable through navigation from the parent immediately. If you also need direct NodeId lookup (e.g. for Read service calls that target the new node by id), invoke AsyncCustomNodeManager.AddPredefinedNodeAsync on the new node from a deferred OnNodeAdded callback.

Creating instances of model types

INodeBuilder.CreateInstance<TState>(name, factory) materialises a new BaseInstanceState subtype using a user-supplied factory delegate — typically a generated Create<TypeName> method from the source generator output. The returned IInstanceBuilder<TState> exposes .Configure(builder => …) for inline child wiring, .AsNode() for a typed INodeBuilder<TState> view, and .Done() to return to the parent builder.

builder.Node("Pumps")
       .CreateInstance(
           new QualifiedName("Pump #2", pumpsNs),
           pumpTypeId,
           parent => context.CreatePumpType(parent))
       .Configure(p2 =>
           p2.AsNode()
             .WithProperty("Manufacturer", "Vendor B")
             .WithProperty("SerialNumber", "SN-002"));

The factory pattern keeps the API reflection-free and AOT safe — the generator already emits the per-type Create<Type> extension methods that the factory delegate calls into.

Alarm setup (MVP)

INodeBuilder.CreateLimitAlarm, .CreateExclusiveLimitAlarm and .CreateOffNormalAlarm attach a fresh alarm condition under the current node and return an IAlarmBuilder<TState> for further configuration:

builder.Node("Pumps/Pump #1/Events")
       .CreateLimitAlarm(new QualifiedName("OverTempAlarm", pumpsNs))
       .WithLimits(highHigh: 380, high: 370, low: 273, lowLow: 263)
       .MonitorVariable(temperatureNode)
       .OnAcknowledge((ctx, condition, eventId, comment) => ServiceResult.Good)
       .OnConfirm((ctx, condition, eventId, comment) => ServiceResult.Good);

For full state access (severity tables, retain flag, branches), use the .ConfigureAlarm(Action<TState>) escape hatch:

builder.Node("Events")
       .CreateLimitAlarm(new QualifiedName("Custom", ns))
       .WithLimits(high: 100)
       .ConfigureAlarm(alarm =>
       {
           alarm.Retain!.Value = true;
           // any state-class mutation goes here
       });

Boolean supervision → alarm activation (NAMUR pattern)

IVariableBuilder<bool>.OnRisingEdge / .OnFallingEdge register callbacks that fire when the variable's value transitions. The .ActivatesAlarm(alarmBuilder) extension wires the bool variable to an AlarmConditionState's ActiveState so it flips in lockstep with the supervision flag — exactly the OPC UA DI / NAMUR NE 107 pattern.

IAlarmBuilder<NonExclusiveLimitAlarmState> cavitationAlarm =
    builder.Node("Events").CreateLimitAlarm(name)
        .ConfigureAlarm(a => a.Severity!.Value = (ushort)EventSeverity.Medium);

builder.Variable<bool>("Pump #1/Events/Supervision/ProcessFluid/Cavitation")
       .ActivatesAlarm(cavitationAlarm);

Detection is value-change based: transitions only fire when something else (an OnWrite handler, a simulation tick, a client write) actually mutates the variable.

Simulation timers

INodeManagerBuilder.Simulation(interval).OnTick(...) registers a periodic background loop owned by the FluentNodeManagerBase. Each tick fires on a PeriodicTimer and is cancelled when the manager is disposed; exceptions inside handlers are logged and do not kill the loop.

partial void Configure(INodeManagerBuilder builder)
{
    builder.Simulation(TimeSpan.FromMilliseconds(250))
        .OnTick((ctx, elapsed) =>
        {
            m_temperature = 313.15 + 5 * Math.Sin(m_t * 0.01);
            m_pressure = 200000 + 50000 * Math.Sin(m_t * 0.03);
            m_t++;
        });
}

Async tick handlers receive a CancellationToken honouring manager disposal — use it for any awaitable work inside the loop. Multiple .OnTick calls on the same Simulation() builder all fire on every tick.

The simulation registry requires the manager to derive from FluentNodeManagerBase (the source generator-emitted manager already does); calling .Simulation() on a plain CustomNodeManager2 throws StatusCodes.BadConfigurationError.

Pushing runtime value changes to subscribers

OnRead getters are invoked on the Attribute (Read) service, but a value that only lives behind a getter — or in a backing field mutated by an OnCall handler — will not reach subscribed MonitoredItems on its own. In previous implementations the fix was to mutate Node.Value and call Node.ClearChangeMasks(...), but that node handle is deliberately unavailable through the fluent surface once Configure returns (the builder is sealed).

Two fluent mechanisms close that gap.

1. Bind(out IValueUpdater<TValue>) — explicit push. Capture a runtime handle during Configure and store it on the manager; the handle survives sealing. SetValue assigns the value, timestamp and status and flushes the change mask in one serialized call, so both reads and subscriptions see the update:

private IValueUpdater<float> m_ao01 = null!;

partial void Configure(IMyNodeManagerBuilder builder)
{
    builder.MyEquipment03.AO01.Builder.AsVariable<float>()
           .Bind(out m_ao01);

    builder.MyEquipment03.SetOutputVal
           .OnCall((float value) => m_ao01.SetValue(value));
}

IValueUpdater<TValue> also exposes SetValue(value, statusCode), SetValue(value, statusCode, sourceTimestamp), and NotifyChange() (flush a notification after an in-place mutation without changing the value).

2. PollEvery(interval, getter) — opt-in auto-sampling. Register a periodic loop that reads the getter and pushes a change only when the value actually differs, so subscriptions update automatically with no change-notification code. An initial sample is applied immediately:

builder.MyEquipment03.AO01
       .PollEvery(TimeSpan.FromMilliseconds(250), () => m_ao01Value);

Like Simulation, PollEvery reuses the manager-owned loop infrastructure and therefore requires the manager to derive from FluentNodeManagerBase; calling it on a plain CustomNodeManager2 throws StatusCodes.BadConfigurationError.

Multi-model composition

The only supported mode for combining models is source-generated library references. Each companion spec is built once into its own model library (a src/Opc.Ua.{Spec}/ project that consumes the ModelDesign XML and emits an AddOpcUa{Spec} extension method); the consumer adds project references and calls the generated extensions directly in dependency order:

protected override ValueTask<NodeStateCollection> LoadPredefinedNodesAsync(
    ISystemContext context, CancellationToken ct = default)
{
    var nodes = new NodeStateCollection();
    nodes.AddOpcUaDi(context);
    nodes.AddOpcUaMachinery(context);
    nodes.AddOpcUaPumps(context);
    return new ValueTask<NodeStateCollection>(nodes);
}

Source-generated models are AOT-friendly, deterministic, and produce typed *State / *Client proxies. Every application- owned model must ship as source-generated content — companion specs ship as project references; locally-owned NodeSet2 XMLs are wired through <AdditionalFiles> so the source generator emits the same typed surface inside the consuming assembly. Each AddOpcUa{Spec}(context) extension is idempotent and re-entrant, so direct chaining in dependency order is the recommended pattern.

Mixing ModelDesign and NodeSet2 in one project

A ModelDesign XML and a NodeSet2 XML can be combined in the same project, and a node in one may reference a type defined in the other. A common split is to author the reusable object types as a NodeSet2 (e.g. exported from a modelling tool such as SiOME) and the concrete instances as a ModelDesign whose TypeDefinition points at those NodeSet2 types:

<!-- Instances.ModelDesign.xml -->
<opc:ModelDesign
  xmlns:opc="http://opcfoundation.org/UA/ModelDesign.xsd"
  xmlns:et="http://example.org/EquipmentTypes"
  xmlns="http://example.org/EquipmentInstances"
  TargetNamespace="http://example.org/EquipmentInstances">
  <opc:Namespaces>
    <opc:Namespace Name="EquipmentInstances"
      >http://example.org/EquipmentInstances</opc:Namespace>
    <!-- Bind the same URI to the "et" XML prefix used below. -->
    <opc:Namespace Name="EquipmentTypes" XmlPrefix="et"
      >http://example.org/EquipmentTypes</opc:Namespace>
  </opc:Namespaces>
  <!-- "et:" resolves to the NodeSet2 namespace declared via xmlns:et. -->
  <opc:Object SymbolicName="Equipment01" TypeDefinition="et:SimpleEquipmentType" />
</opc:ModelDesign>
<Project>
  <ItemGroup>
    <AdditionalFiles Include="Model\EquipmentTypes.NodeSet2.xml">
      <ModelSourceGeneratorModelUri>http://example.org/EquipmentTypes</ModelSourceGeneratorModelUri>
    </AdditionalFiles>
    <AdditionalFiles Include="Model\Instances.ModelDesign.xml">
      <ModelSourceGeneratorModelUri>http://example.org/EquipmentInstances</ModelSourceGeneratorModelUri>
    </AdditionalFiles>
  </ItemGroup>
</Project>

The generator resolves the cross-model reference automatically — every input is supplied to the others as a resolution dependency (both ModelDesign → NodeSet2 and ModelDesign → ModelDesign).

Binding a [NodeManager] in a mixed project. A [NodeManager] may target the namespace of either input — the NodeSet2 type model or the ModelDesign instance model — by setting its NamespaceUri to that model's URI. Binding is resolved across both the NodeSet2 and the ModelDesign generation passes, so a manager bound to the NodeSet2 types is not reported as unmatched (MODELGEN010) just because the project also contains a ModelDesign — and vice-versa. The generated node-manager class name and namespace come from the annotated partial class itself, not from ModelSourceGeneratorPrefix/Name (those control the generated *State/type class names — see the note below).

C# namespace of a NodeSet2 model. The generated C# namespace for a NodeSet2 input is derived from its ModelUri unless you set ModelSourceGeneratorPrefix (C# namespace / prefix) and ModelSourceGeneratorName (the Namespaces class identifier) on that AdditionalFiles entry. A Prefix/Name declared inside a referencing ModelDesign's <opc:Namespaces> does not rename the NodeSet2's generated types — set the per-file MSBuild metadata on the NodeSet2 entry to control it.

Current limitations

  • Browse-path wildcards (*, **) are not supported. Wire each path explicitly or resolve by NodeId / TypeDefinitionId.
  • HistoryRead/Update integration is delegate-only in v1; deeper paging/queueing still requires INodeManager2 work.
  • Reserved child names. A component/property whose BrowseName matches a built-in NodeState attribute member (for example Description or DisplayName) shadows that member on the generated *State class and produces code that does not compile. Rename such children (the OPC UA Description/DisplayName attributes are always available without a dedicated child).

Sample

  • samples/MinimalBoilerServer/ — a fully self-contained, NativeAOT single-file Boiler server. Read it top-to-bottom in <200 lines.
  • samples/MinimalCalcServer/ — a calculator server that exercises the typed methods-with-arguments OnCall overloads end-to-end (sync int+int → int, async double+double → double, sync string+string → string).
  • samples/PumpDeviceIntegrationServer/ — the full OPC 40223 Pumps companion server. Exercises every fluent extension above (engineering units, identification properties, FunctionalGroup wiring, instance creation, limit alarm with NAMUR-style boolean supervision, periodic simulation tick, and multi-model loader for DI + Machinery + Pumps), and additionally attaches the OPC 10000-100 software-update facet to a second declarative pump device.