Calibration and setup

Run so101 setup to open the bundled browser UI. Use the sidebar to choose Calibrate arm or Program motor IDs. From a source checkout, build the browser assets and run the Rust CLI:

pnpm install --frozen-lockfile
pnpm build
cargo run --manifest-path setup/native/Cargo.toml -- setup

To update an executable installed directly from GitHub Releases, close the running setup session and run so101 update. The command selects the archive for your platform, verifies its SHA-256 digest from GitHub, and replaces the executable in place. Run so101 update --check to check without installing. Use your package manager for a package-managed install.

To prepare loose STS3215 servos for a follower, open Program motor IDs. Choose New follower batch to program IDs 1–6 in order, skipping motors you do not need. The checklist distinguishes skipped motors from verified ones. Choose Program one ID to program any number of motors with the same joint ID; the last successfully programmed ID is remembered on this browser. Disconnect any active calibration session first. Turn off servo power before connecting or swapping motors, and connect only the loose servo being programmed. The tool reads back the ID at 1 Mbps before marking it verified. Label each motor with its verified joint and ID, then install and daisy chain the motors during assembly.

Open Calibrate arm after assembly and select its USB controller. On a fresh launch, the calibration page selects a single connected controller automatically. Support the disabled arm in the shown resting pose with the gripper closed, then start recording and gently sweep each joint through its safe travel, including wrist roll and gripper opening. The tool flags unusually short sweeps so you can continue recording any missed joint. Never force a joint to satisfy the check. Review and adjust the live model before saving. The home pose is an estimate, so compare multiple positions.

If one joint needs a fresh calibration, open the arm’s saved setup and choose Recalibrate one joint on the review screen. This option is available when the saved calibration matches the motor registers. Select the joint, set it to the reference shown, then start the sweep and move it by hand through its safe travel. Finish the sweep and confirm its live direction and alignment before saving. Save updates that joint’s calibration and leaves the other joints and servo gains intact. Discard joint calibration returns to the saved setup.

The server reads motor positions and streams updates to the browser. Streaming does not increase the motor sampling rate; move slowly and pause at endpoints so the tool can record the full range.

Draft capture and range recording change no registers. Save backs up the prior files/registers, writes and verifies calibration/settings with torque off, then releases the port. If save fails, reconcile the recorded backup before control. The tool never enables torque or sends position goals.

ArmSetup holds serial identity, motor ID order, model alignment, gripper endpoints, and expected servo settings. Setup writes arms/<serial>/setup.toml and LeRobot-compatible calibration.json. The default store is $SO101_SETUP_DIRECTORY, otherwise $XDG_CONFIG_HOME/so101-setup (defaulting to ~/.config/so101-setup).

Motor IDs may run from 1 to 6 or from 6 to 1 from the base to the gripper. The default is ascending. For a different order, open Edit motor mapping during the full sweep. Choose an ascending or descending shortcut, or assign each motor ID to a joint. IDs 1 through 6 must each appear once. Move the joints by hand with torque off to verify the correspondence. Save records the mapping in the [motor_ids] table and leaves the programmed servo IDs intact.

New arms default to the soft gripper with wrist camera and start calibration in the resting pose. For stock gripper geometry, start with so101 setup --model-variant stock. Existing arms keep the model_variant in their setup.toml; to change an existing arm's model, edit that field before starting the tool. The viewer selects the corresponding model and saving calibration preserves the selection. This selects geometry; it does not recalibrate an existing arm or establish camera optical calibration.

See coordinate conventions, development/build commands, and the official LeRobot guide. Use an external control application for powered operation. This workflow still requires validation on the particular physical arm.

A full calibration save writes the standard servo registers that every arm runs, defined once in the runtime's servo_registers module: position gains (P/I/D 32/0/32 on the shoulder lift and elbow, 16/0/32 elsewhere), return delay 0 and maximum acceleration 254 on all six motors, and gripper maximum torque 500 and protection current 250. These are raw register values. A single-joint recalibration leaves them alone. The legacy Python setup still carries its own copy of these values.

For an arm that needs different values, manually add servo-overrides.toml beside its setup.toml. Set only the keys it needs: maximum_acceleration, gripper_max_torque_limit, or gripper_protection_current. The tool applies them on the next full save. New arm setups do not create this file. The simulated servo response is fitted to the standard registers, so it does not describe an arm with overrides.

Reset servo parameters

Stop the motion station and close the calibration tool. With the arm supported, all six servos powered and torque off, run:

so101 servo reset --serial BOARD_SERIAL --motor-id 4 --confirm

This sends a parameter restore to the specified ID on the daisy chain. It requires six responding servos and a target STS3215 reporting model 777 and firmware 3.10. Connect only one arm to the chosen board and make sure its motor IDs are unique. Before and after snapshots go under the arm's backups/ directory. The restore changes the target servo's stored parameters, including calibration. Restore its calibration and verify it with torque off before enabling the arm.

Use --all in place of --motor-id to reset all six. This is the same reset offered before a full calibration. A partial full reset must be retried before calibration can proceed.

Calibrate from the terminal

Run a setup service in one terminal so it can keep sampling during the sweep:

so101 setup --no-browser

In a second terminal, select the controller, choose whether to reset, and capture the reference and sweep:

so101 list
so101 calibrate begin --serial BOARD_SERIAL --skip-reset
so101 calibrate sweep start
# Move each joint by hand through its safe range.
so101 calibrate sweep finish
so101 calibrate review --watch

If the arm opens to an existing calibration review, run so101 calibrate restart and choose whether to reset before starting a new full sweep.

Use so101 calibrate map 6,5,4,3,2,1 during the full sweep to change the physical motor-to-joint mapping. Use so101 calibrate check-order before and after moving only the base, then so101 calibrate apply-order to apply the detected order. During review, so101 calibrate reverse shoulder-pan changes direction, and so101 calibrate adjust shoulder-pan -0.02 changes its offset in radians. Check the reported angles and direction against the physical arm. so101 calibrate save displays the draft and asks for confirmation. For scripts, pass --confirm --revision <revision> with the revision from so101 calibrate review --json.

To recalibrate one joint, connect to a saved setup that matches the arm, then run so101 calibrate sweep start --joint shoulder-pan. Finish, review, and save the same way. Use so101 calibrate restart to discard the draft, or so101 calibrate disconnect to release the controller.

To program a loose motor's physical ID, stop calibration or disconnect the arm, then connect and power just the loose servo. List adapters and program the ID:

so101 list --adapters
so101 servo id --port USB_PORT --motor-id 4 --isolated